Power Distribution
Basic Rack PDU
(1.4 kW - 12.5 kW, 15A - 50A, Horizontal or Vertical Mount)
Power distribution for rack-mount equipment
The most mounting options in the market.
APC offers a wide variety of Basic Rack Power Distribution
Units (PDUs), which allow users to distribute power outlets
to rack-mount equipment. Horizontal and vertical units are
available as well as a variety of power inputs and outputs
to fit most power environments. APC now offers Basic Rack
PDUs that mount vertically, without tools in the rear channel
of a NetShelter VX.
Metered Rack PDU
(1.4 kW - 12.5 kW, 15A - 50A, Horizontal or Vertical Mount)

Power distribution units that monitor the aggregate power consumption
of connected equipment The most user-friendly network interface for monitoring current
APC's Metered Rack Power Distribution Units (PDUs) provide
power distribution as well as equips on-site installers with
the ability to monitor the aggregate current draw as equipment
is connected to the unit. These Metered Rack PDUs also have
alarm thresholds that when exceeded alert users of potential
problems. These features help eliminate the possibility of
an overloaded circuit.
Switched Rack PDU
(1.4 kW - 12.5 kW, 15A - 50A, Horizontal or Vertical Mount)

Power distribution that remotely controls power to individual
outlets and monitors the aggregate power consumption The first Rack PDU with high power density and switchable
outlets
APC’s Switched Rack Power Distribution Units (PDUs) are
premium solutions to many of the power management problems
seen in today’s IT environments. Some of the problems
are unauthorized use of power outlets, locked-up equipment,
in-rush current, overloaded circuits, and the need of remote
access to power outlets in the rack. The Switched Rack PDUs
address these problems through individual outlet control, power
on and off delays, current monitoring, alarm thresholds, and
network management. Individual outlet control allows users
to turn outlets on, turn outlets off, or recycle power to equipment,
which can reboot locked-up equipment and avoid unauthorized
use of outlets. Power delays allow users to determine the order
in which equipment is powered up or down. Utilizing the power
delay feature will avoid in-rush current, which can cause overloads.
Monitoring the current draw at the rack level is key to avoiding
downtime due to overloaded circuits. The Switched Rack PDUs
provide an aggregate current draw, which can be viewed remotely
or locally, via digital display. In addition, alarms will be
generated based on user-defined thresholds to alert users of
potential circuit overloads (NOTE: Currently available on select
models only. Please see feature list for availablity per SKU).
Users can access, configure, and control the Switched Rack
PDUs through Web, SNMP, or Telnet Interfaces.
Rack Automatic Transfer Switch
(1.4 kW - 5.7 kW, 15A - 30A, Networked and Non-networked)

Provides redundant power to single-corded equipment. The only manageable transfer switch in 1U
APC’s Rack Automatic Transfer Switch (ATS), also known
as the Redundant Switch, is a high availability switch that
has two input power cords, one for each AC line, which provide
redundant power to connected equipment. The Rack ATS is designed
to supply power to the connected load from a primary AC source.
If that primary source becomes unavailable for whatever reason,
the Rack ATS will automatically begin sourcing power from the
secondary source. The transfer time from one source to the
other is seamless to the connected equipment. The Networked
units have built-in network connectivity, which allows for
remote management via Web, SNMP, or Telnet interfaces.
Rack PDU Accessories

Cord retention brackets
and vertical-mount bracket kits to complete rack power distribution
solutions APC's Rack PDU Accessories contain bracket kits specifically
designed to mount many of APC's vertical Rack Power Distribution
Units (PDUs) into third party racks or enclosures as well as
a cord retention bracket to help retain power cord connection
to the Rack PDUs. Specially designated SKUs in the Basic, Metered,
and Switched Rack PDUs can utilize these bracket kits. See
features list to see if your Rack PDU is compatible with these
brackets. See model names for rack vendor compatibility.
InfraStruXure™ Power Distribution Units
(3-Phase 40, 60, 80, and 150 kW)

Configured to order, factory assembled power distribution for
Information Technology (IT) equipment in medium to large
data centers Simplify installation at half the cost
The Configure-to-order (CTO) process allows for the pre-installation
of pretested breakers, cut-to-size power whips, load-test
ports, and branch circuit monitoring boards. Build your InfraStruXure
PDU to your exact specifications to increase speed of deployment,
reliability, and cost savings. Integrated System Bypass Panel
allows for UPS isolatation from the critical load. Equipped
with circuit breaker panels to effectively distribute power
to connected loads.
Power Cords
(2 ft (0.6 m) - 15 ft (4.6 m))

Power connector options for a variety of IT equipment
APC offers power cords (also known as jumper cords), which
provide connector options to fulfill a variety of power requirements.
Use these power cords to connect your equipment to an APC Rack-Mount
power distribution unit (PDU)/outlet strip, MasterSwitch product,
Automatic Transfer Switch (ATS), or UPS.
These power cords can also be used to connect your APC Rack-Mount
(PDU)/Outlet Strip to a power source, such as an APC UPS, ATS,
or separate branch circuit. |