DIALOG DUAL
DIALOG DUAL 3300-4000VA floor or 19"
 An
Uninterruptible Power System (UPS) for medium sized file servers
and telecomms switches for floor or 19" rackmount
applications
The Riello Galatrek DIALOG DUAL Uninterruptible
Power Supply range is available in 3300-4000VA models, with
on-line double
conversion (VFI) technology. The DIALOG DUAL range may be placed
directly on the floor or mounted in 19" rackmount cabinets
such as the Multi Shelter range.In terms of technology, features
(selectable On-line, Economy and Smart Active operating modes),
and diagnostics such as the digital display, RS232 and USB interfaces,
network adaptor card option and PowerShield² software included.
DIALOG DUAL is easily the best solution for protecting mission
critical applications requiring the highest levels of reliability.
DIALOG DUAL is ideally suited for a whole range of applications
from IT to security.
FLEXIBILITY OF INSTALLATION AND USE
•
the UPS can be installed as a floor standing tower or 19” rackmount.
The front panel digital display can be pulled out (using the
keys provided) and rotated to suite the installation format
•
low noise level (<40dBA) thanks to the digitally PWM controlled
ventilation system which is load and temperature dependent,
and the use of an inverter with a high switching frequency
(>20kHZ, above the audible range). DIALOG Dual is suitable
for installation in any populated environment.
USER SELECTABLE CUSTOMISATION OPTIONS
• Operating modes:
– On-line (VFI): the inverter powers the load continuously
– Economy: the UPS mimics a Line Interactive (VI) UPS supporting
the load from its battery supply when the mains fails or fluctuates
wildly
– Smart Active: the UPS selects automatically whether to operate
in On-line (VFI) or Line Interactive (VI) mode depending on the
stability of the mains supply
– Emergency: the UPS only supports the load with its batteries
when the mains fails - suitable for emergency lighting
– Frequency conversion 50 or 60Hz
• Output voltage selection: 220-230-240Vac
•
Auto restart on mains return set from the front panel or PowerShield² software
• Automatic output delay when the UPS powers up
• Automatic power down when no load is present
• End of battery discharge pre-alarm.
QUALITY OF POWER SUPPLY
• Filtered, stable and regulated - double conversion on-line (VFI)
technology in accordance with
EN50091-3, a with EMI filters
• Guaranteed output quality even with typical distorting IT loads
with crest factors of 3:1
• Low impact on the mains supply as the UPS has an input power
factor close to 1, with a sinusoidal input current.
HIGHLY RELIABLE
• Completely digitally controlled
• Uninterrupted automatic by-pass
• The by-pass can be activated manually
• Use of IMS (Insulated Metallic Substrates) modules.
ADVANCED DIAGNOSTICS
• Status, measurements, and alarms available on the standard backlit
display
• UPS can be updated digitally (flash upgradeable).
OPTIMAL BATTERY MANAGEMENT
• Reliable battery performance (automatic and
manual battery tests)
• Prolonged battery life due to the unique Low Ripple Current Discharge
(LRCD)
•
‘Hot-swap’ user replaceable batteries
• Extendible back-up time using additional Battery
Extension Packs or Trays
• Increased ride through (without batteries) on mains breaks up
to 40ms and for fluctuations ranging from 84 to 276Vac.
ENHANCED ELECTRICAL PERFORMANCE
• Input protected by resettable thermally activated switch
• Back-feed protection: to avoid energy being fed back into the
mains should a fault occur
• Increased short circuit current on the by-pass
• Increased overload capacity: 150% on inverter even
without a mains supply present
•
Performance guaranteed in temperatures up to 40°C
• Manual switch to by-pass.
MICROSOFT CERTIFICATION
The UPS and communication software have been certified by MicroSoft
laboratories
Click here for Dialogue Dual Brochure (PDF 334KB) |