Cooling Systems
Hot Aisle Containment
(19" or 23" Netshelter VX Enclosure)  Hot aisle containment for high-density configurations. The only enclosed hot aisle solution.
Mixing of hot and cold air streams in the data center lowers availability
of IT equipment. Returning the warmest possible air to the computer
room air conditioners increases the efficiency and capacity of the
system. The hot aisle containment system ensures proper air distribution
by completely separating supply and return air paths.
The hot aisle is sealed off using doors and transparent ceiling tiles
that extend the width of the hot aisle. Ceiling tiles are available for
both 19" and 23" racks. Two-rack kits complete with ceiling
tile and hardware are available for future expansion.
Rack Air Removal Unit
(120v and 208/230v models)  Heat Removal for High-Density Enclosures. The only manageable rack heat removal solution.
Densely packed enclosures can overheat IT equipment and cause downtime.
High-density enclosures create an environment where traditional air
distribution methods are not effective.
The Air Removal Unit captures exhaust heat, ducting it to the return
air plenum and eliminating hot spots. Through automatic fan speed adjustment
based on temperature or power consumption, a desired temperature can
be set and fans will self-adjust for optimal energy efficiency.
The Rack Air Removal Unit provides fan redundancy in the event of fan
failure, and power redundancy through dual corded input. This space saving
product mounts to the back of the enclosure - requiring zero U space. Back to Top
Rack Air Distribution Unit
(100v, 120v, 208/230v models)  Air Distribution for Power Dense Enclosures and Low Pressure Areas. The first product to distribute conditioned air directly into the
enclosure.
The Rack Air Distribution Unit is a 2U fan unit that works with an existing
precision air conditioning system to deliver cool air to the equipment
contained in a rack enclosure. The Rack Air Distribution Unit connects
into the raised floor and pulls supply air directly into the enclosure.
This prevents the conditioned air from mixing with warmer room air before
reaching the equipment.
The Rack Air Distribution Unit minimizes temperature differences between
the top and bottom of the enclosure. It also prevents hot exhaust air
from recirculating to the inlet of the enclosure.
The product is recommended for rack enclosures with loads greater than
1.5kW and can provide airflow for loads up to 3.5kW. It is also ideal
for enclosures in raised floor environments where underfloor air distribution
is inadequate Back to Top
Rack Side Air Distribution Unit
(120v and 208/230v models)  Air distribution for networking equipment with side to side airflow. The first air distribution product for high-density equipment with
side to side airflow
Housing equipment with side to side airflow creates many challenges for
IT and facility managers, particularly in regards to cooling. Because
most enclosures are designed for a front to back airflow pattern, it
is difficult to maintain ideal operating temperatures on side to side
airflow equipment. The Rack Side Air Distribution Unit allows for greater
security and organization by allowing racks to be placed adjacent to
one another without impeding airflow.
The Rack Side Air Distribution Unit is a 2U rack mountable air distribution
product for networking equipment or servers with side to side airflow.
It pulls in conditioned air from the front of the rack and distributes
it to the side air intake of the networking equipment. This extends equipment
life by providing proper inlet temperatures.
This product is recommended for one or more networking products that
are stacked consecutively in a rack. Rack Side Air Distribution Units
may be placed above and/or below the networking equipment. Airflow pattern
is user configurable via an interchangeable air turning vane.
NetworkAIR™ FM
(Available with four heat rejection methods: Air, Water,
Glycol, and Chilled Water. MultiCool and Economizer are available in
North America only.)  Modular Floor Mount Precision Air Conditioning for environmentally
sensitive equipment areas.
The world's only computer room air conditioning system built on twenty-first
century technology.
The NetworkAIR FM utilizes leading edge precision air technologies. Modular
construction, variable frequency drives, dedicated de-humidification,
tandem scroll compressors, and front service access are all integrated
into one high efficiency system. A scalable design enables customers
to meet the changing needs of their environments. Click
here for NetworkAIR FM Brochure (PDF 924KB)
NetworkAIR™ IR
(40kW (12 ton) chilled water configuration)  In-Row precision air conditioning for data centers and computer rooms. The world's only computer room air conditioning system with horizontal
airflow for in-row operation.
Data center heat densities continue to increase, making it more difficult
to provide adequate cooling. The distance between heat sources and heat
removal systems must decrease to ensure proper airflow paths. The closer
to the heat generation source the air conditioner is, the less likely
mixing of hot and cold air streams will occur.
The NetworkAIR IR is a computer room air conditioning system with a horizontal
airflow pattern specifically designed for hot aisle/cold aisle configurations.
Warm exhaust air is drawn from the hot aisle, cooled, and distributed
into the cold aisle, ensuring that equipment inlet temperatures will
be constant and adequate for proper operation.
Closely coupling the air conditioner with the heat source produces warmer
return air to the system. This increases the heat removal capacity of
the system and nearly eliminates the need for make-up humidification. |